TESTING & COSMETIC NOTES:
This is a USED WORKING item in GOOD cosmetic condition that IS THOROUGHLY TESTED and is GUARANTEED WORKING
Hard drive has been erased via NIST SP 800-88r1 Clear and vigorously tested to have all good sectors. There is no information or data on the drive. Unit has 100% remaining health. These units are in GRADE B cosmetic shape. HDD label will have some sort of scratch or tear. Please see photo for representative sample.
COMPONENTS INCLUDED IN THIS SALE:
• (1) – HPE MB010000GWAYN 857643-002 HUH721010ALE604 10TB 7.2K RPM SATA 6GBPS 3.5″ HDD
REPLACEMENT or MONEY BACK GUARANTEE:
When you receive a Guaranteed item from OC Depot, it should perform as described. In the rare situation that this is not the case, we will send a replacement upon safe return of the original item within 30 days of receiving the item. If a replacement is not available we will honor the terms of our Money-Back Guarantee.
ADDITIONAL INFORMATION:
=== START OF INFORMATION SECTION ===
Device Model: MB010000GWAYN
Serial Number: 7PG77P2R
LU WWN Device Id: 5 000cca 251c34b6d
Firmware Version: HPG3
User Capacity: 10,000,831,348,736 bytes [10.0 TB]Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sun Mar 3 05:21:10 2024 UTC
SMART support is: Available – device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 93) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: (1087) minutes.
SCT capabilities: (0x0025) SCT Status supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 100 095 016 Pre-fail Always – 0
2 Throughput_Performance 0x0027 134 100 054 Pre-fail Always – 96
3 Spin_Up_Time 0x0023 157 100 024 Pre-fail Always – 440 (Average 400)
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always – 0
7 Seek_Error_Rate 0x002f 100 100 067 Pre-fail Always – 0
8 Seek_Time_Performance 0x0025 128 100 020 Pre-fail Offline – 18
9 Power_On_Hours 0x0032 094 094 000 Old_age Always – 46873
10 Spin_Retry_Count 0x0033 100 100 060 Pre-fail Always – 0
22 Unknown_Attribute 0x0023 039 039 025 Pre-fail Always – 42
169 Unknown_Attribute 0x0033 100 100 099 Pre-fail Always – 0
180 Unknown_HDD_Attribute 0x002b 100 100 098 Pre-fail Always – 0
194 Temperature_Celsius 0x0022 206 136 000 Old_age Always – 29 (Min/Max 20/44)
196 Reallocated_Event_Count 0x0033 100 100 000 Pre-fail Always – 0
SMART Error Log not supported
SMART Self-test Log not supported
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.